Open Access
Issue
E3S Web Conf.
Volume 172, 2020
12th Nordic Symposium on Building Physics (NSB 2020)
Article Number 05005
Number of page(s) 6
Section Air leakage
DOI https://doi.org/10.1051/e3sconf/202017205005
Published online 30 June 2020
  1. A. Miszczuk, “Influence of air tightness of the building on its energy-efficiency in single-family buildings in Poland,” MATEC Web Conf., vol. 117, 2017. [Google Scholar]
  2. C. Younes, C. a. Shdid, and G. Bitsuamlak, “Air infiltration through building envelopes: A review,” J. Build. Phys., vol. 35, no. January, pp. 267–302, 2012. [Google Scholar]
  3. G. Raman, K. Chelliah, M. Prakash, and R. T. Muehleisen, “Detection and quantification of building air infiltration using remote acoustic methods,” INTERNOISE 2014-43rd Int. Congr. Noise Control Eng. Improv. World Through Noise Control, no. January, 2014. [Google Scholar]
  4. W. R. Chan, W. W. Nazaroff, P. N. Price, M. D. Sohn, and A. J. Gadgil, “Analyzing a database of residential air leakage in the United States,” Atmos. Environ., vol. 39, no. 19, pp. 3445–3455, 2005. [Google Scholar]
  5. CEN, “EN ISO 52016-1:2017: Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads – Part 1: Calculation procedures.” 2017. [Google Scholar]
  6. M. Kraus and D. Kubečkova, “Airtightness of Energy Efficient Buildings,” Annu. Int. Conf. Archit. Civ. Eng. Singapore, 2013. [Google Scholar]
  7. W. Bracke, J. Laverge, N. Van Den Bossche, and A. Janssens, “Durability and Measurement Uncertainty of Airtightness in Extremely Airtight Dwellings,” Int. J. Vent., vol. 14, no. 4, pp. 383–393, 2016. [CrossRef] [Google Scholar]
  8. J. Reiß and H. Erhorn, “Messtechnische Validierung des Energiekonzepts einer großtechnisch umgesetzten Passivhausentwicklung in Stuttgart-Feuerbach,” IBP-Bericht WP, vol. 117, 2003. [Google Scholar]
  9. H. Erhorn, H. Erhorn-Kluttig, and R. Carrié, “Airtightness requirements for high performance buildings,” in Proceedings 29th AIVC Conference 2008, 2008, pp. 25–32. [Google Scholar]
  10. G. Proskiw and P. Eng, “Variations in Airtightness of Houses Constructed with Polyethylene and ADA Air Barrier Systems Over a Three-Year Period,” Therm. Insul. Build. Envel., vol. 20, no. April 1997, pp. 278–296, 1997. [CrossRef] [Google Scholar]
  11. M. H. Sherman, “Tracer-gas techniques for measuring ventilation in a single zone,” Build. Environ., vol. 25, no. 4, pp. 365–374, 1990. [Google Scholar]
  12. T. Patel, C. Mitsingas, J. P. Miller, and T. A. Newell, “Comparison of blower door and tracer gas testing methods for determination of air infiltration rates through building envelopes at normal operating conditions,” ASME 2011 5th Int. Conf. Energy Sustain. ES 2011, no. PARTS A, B, AND C, pp. 1013–1019, 2011. [Google Scholar]
  13. ASTM E741, “Standard test method for determining air change in a single zone by means of a tracer gas dilution,” 2000. [Google Scholar]
  14. S. Cui, M. Cohen, P. Stabat, and D. Marchio, “CO2 tracer gas concentration decay method for measuring air change rate,” Build. Environ., vol. 84, pp. 162–169, 2015. [Google Scholar]
  15. EN ISO 9972:2015, “Determination of air permeability of buildings–Fan pressurization method,” 2015. [Google Scholar]
  16. J. Kronvall, “Correlating Pressurization and Infiltration Rate Data-Tests of an Heuristic Model,” Lund Inst. Technol. Div. Build., 1980. [Google Scholar]
  17. VEA, “EPB-CIJFERRAPPORT Procedures, resultaten en energetische karakteristieken van het Vlaamse gebouwbestand - periode 2006-2018. (in Dutch),” 2019. [Google Scholar]
  18. B. P. Jelle, “Traditional, state-of-the-art and future thermal building insulation materials and solutions - Properties, requirements and possibilities,” Energy and Buildings. 2011. [Google Scholar]
  19. S. Baldi, T. Le Quang, O. Holub, and P. Endel, “Real-time monitoring energy efficiency and performance degradation of condensing boilers,” Energy Convers. Manag., vol. 136, pp. 329–339, 2017. [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.