Open Access
Issue |
E3S Web Conf.
Volume 343, 2022
52nd AiCARR International Conference “HVAC and Health, Comfort, Environment - Equipments and Design for IEQ and Sustainability”
|
|
---|---|---|
Article Number | 03002 | |
Number of page(s) | 14 | |
Section | HVAC Impact on Comfort and Health of Occupants and Operators | |
DOI | https://doi.org/10.1051/e3sconf/202234303002 | |
Published online | 08 March 2022 |
- Ai Z.T., Melikov A.K. Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review. Indoor Air 28, 500-524. (2018) [CrossRef] [PubMed] [Google Scholar]
- Bedell K, Buchaklian AH, Perlman S. Efficacy of an automated multiple emitter whole-room ultraviolet-C disinfection system against coronaviruses MHV and MERS-CoV. Infect Control Hosp Epidemiol 37: 598 –599 (2016) [CrossRef] [PubMed] [Google Scholar]
- Buonanno G., Morawska L. Stabile, L. Quantitative assessment of the risk of airborne transmission of SARS-CoV-2 infection: Prospective and retrospective applications. Environmental International, 45, art. n. 106112 (2020) [CrossRef] [Google Scholar]
- Buonanno G., d’Ambrosio F.R., Strada M., Vio M.: La climatizzazione dell’aria: riflessioni suggerite dalla Covid 19, Editoriale Delfino (2021) [Google Scholar]
- Dietz L., Horve P., Coil D., Fretz M., Eisen J, Van Den Wymelenberga K: 2019 Novel Coronavirus (COVID-19) Pandemic: Built Environment Considerations To Reduce Transmission, American society for microbiology, Volume 5 (2020) [Google Scholar]
- Gammaitoni L., Nucci M.C. Using a mathematical model to evaluate the efficacy of TB control measures. Emerging Infectious Diseases, 335-342 (1997) [CrossRef] [PubMed] [Google Scholar]
- Knibbs L.D., Morawska L., Bell S.C., Grzybowsky P. Room ventilation and the risk of airborne innfection transmission in health care settings within a large teaching hospital. American Journal of Infection Control, 39(10), 866-872 (2011) [CrossRef] [PubMed] [Google Scholar]
- Lee B. U.: Life Comes from the Air: A Short Review on Bioaerosol Control, Aerosol and Air Quality Research, 11: 921–927 (2011) [CrossRef] [Google Scholar]
- Lee B. Bahnfleth W.P.: Effects of installation location on performance and economics of in-duct ultraviolet germicidal irradiation systems for air disinfection, Building and environment 67, 193-201 (2013) [CrossRef] [Google Scholar]
- Magurano F., Baggieri M., Marchi A., Rezza G., Nicoletti L. : SARS-CoV-2 infection: the environmental endurance of the virus can be influenced by the increase of temperature, Clinical Microbiology and Infection 27, 289.e5 – 289.e7 (2021) [CrossRef] [Google Scholar]
- Riley EC, Murphy G, Riley RL. Airborne spread of measles in a suburban elementary school. Am J Epidemiol; 107:421-32 (1978) [CrossRef] [PubMed] [Google Scholar]
- Schuit M, Gardner S, Wood S, Bower K, Williams G, Freeburger D, Dabisch P. The influence of simulated sunlight on the inactivation of influenza virus in aerosols. J Infect Dis 221:372–378 (2020) [CrossRef] [PubMed] [Google Scholar]
- van Doremalen N., Bushmaker T. and oth... Aerosol and Surface Stability of SARSCoV-2 as Compared with SARS-CoV-1. N Engl J Med. (2021). [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.