Open Access
Issue |
E3S Web Conf.
Volume 356, 2022
The 16th ROOMVENT Conference (ROOMVENT 2022)
|
|
---|---|---|
Article Number | 02015 | |
Number of page(s) | 4 | |
Section | Underground Environment and Specialized Application | |
DOI | https://doi.org/10.1051/e3sconf/202235602015 | |
Published online | 31 August 2022 |
- Beard A, Carvel R. Handbook of tunnel fire safety [M]. ICE publishing, 2012. [Google Scholar]
- Chow W, MA E Y, IP M K. Recent experimental studies on blocking heat and smoke by a water curtain [J]. International Journal on Engineering Performance-Based Fire Codes, 2011, 10(4): 89-95. [Google Scholar]
- Amano R, Izushi Y, Kurioka H, et al. Water Screen Fire Disaster Prevention System in Underground Space [J]. Fire Safety Science, 2004, 6: 6c-5--1. [Google Scholar]
- Chen L, Zhu W, Cai X, et al. Experimental study of water mist fire suppression in tunnels under longitudinal ventilation [J]. Building and Environment, 2009, 44(3): 446-55. [CrossRef] [Google Scholar]
- Grant G, Brenton J, Drsdale D. Fire suppression by water sprays [J]. Progress in Energy and Combustion Science, 2000, 26(2): 79-130. [CrossRef] [Google Scholar]
- Yang P, Liu T, Qin X. Experimental and numerical study on water mist suppression system on room fire [J]. Building and Environment, 2010, 45(10): 2309-16. [CrossRef] [Google Scholar]
- Ingason H. Model scale tunnel tests with water spray [J]. Fire Safety Journal, 2008, 43(7): 512-28. [CrossRef] [Google Scholar]
- Hart R A. Numerical modelling of tunnel fires and water mist suppression [D]; University of Nottingham, 2005. [Google Scholar]
- Jenft A, Collin A, Boulet P, et al. Experimental and numerical study of pool fire suppression using water mist [J]. Fire Safety Journal, 2014, 67: 1-12. [CrossRef] [Google Scholar]
- Nmira F, Consalvi J L, Kaiss A, et al. A numerical study of water mist mitigation of tunnel fires [J]. Fire Safety Journal, 2009, 44(2): 198-211. [CrossRef] [Google Scholar]
- Li Q, Zhang P, Guo S, et al. Experimental Study on Suppression of n-Heptane Pool Fire with Water Mist under Longitudinal Ventilation in Long and Narrow Spaces [J]. Procedia Engineering, 2013, 62: 946-53. [CrossRef] [Google Scholar]
- Sun J, Fang Z, Tang Z, et al. Experimental study of the effectiveness of a water system in blocking fire-induced smoke and heat in reduced-scale tunnel tests [J]. Tunnelling and Underground Space Technology, 2016, 56: 34-44. [CrossRef] [Google Scholar]
- Oka Y, Oka H. Velocity and temperature attenuation of a ceiling-jet along a horizontal tunnel with a flat ceiling and natural ventilation [J]. Tunnelling and Underground Space Technology, 2016, 56: 79-89. [CrossRef] [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.