Open Access
| Issue |
E3S Web Conf.
Volume 717, 2026
2026 8th International Conference on Environmental Prevention and Pollution Control Technologies (EPPCT 2026)
|
|
|---|---|---|
| Article Number | 01004 | |
| Number of page(s) | 7 | |
| Section | Water and Air Pollution Control | |
| DOI | https://doi.org/10.1051/e3sconf/202671701004 | |
| Published online | 05 June 2026 | |
- Mathanlal T, Zorzano M P, Martin-Torres J. Design, development, and operation of an ISO class 5 cleanroom for planetary instrumentation and planetary protection protocols[J]. Heliyon, 2024, 10(17). [Google Scholar]
- Zhao W, Li H, Wang S. Energy performance and energy conservation technologies for high-tech cleanrooms: State of the art and future perspectives[J]. Renewable and Sustainable Energy Reviews, 2023, 183: 113532. [Google Scholar]
- Bhattacharya A, Tak M S N, Shoai-Naini S, et al. A systematic literature review of cleanroom ventilation and air distribution systems[J]. Aerosol and Air Quality Research, 2023, 23(7): 220407. [Google Scholar]
- Liu K, Hao M, Li B, et al. Optimization on flow field in an operational cleanroom subject to kinematic component and structural parameters[J]. Journal of Building Engineering, 2022, 59: 105152. [Google Scholar]
- Nikoopayan Tak M S, Bhattacharya A, Metcalf A R, et al. Cleanroom air quality: combined effects of ventilation rate and filtration schemes in a laboratory cleanroom[J]. Building Research & Information, 2023, 51(6): 717–729. [Google Scholar]
- Li C, Li H, Zhang M, et al. The research on the particle concentration distribution of directed airflow in cleanrooms for operators[J]. Plos one, 2024, 19(3): e0296803. [Google Scholar]
- Zhao F Y, Cheng J, Liu B, et al. Indoor airflow and pollutant spread inside the cleanroom with micro-porous supplying panel and different ventilation schemes: Analytical, numerical and experimental investigations[J]. Journal of Building Engineering, 2020, 31: 101405. [Google Scholar]
- Chengxi Y, Seungjae L, Dongbin H, et al. Numerical modelling on dispersion behavior of particulate contamination induced by a moving operator in a semiconductor cleanroom: A Eulerian-Eulerian method[J]. Journal of Building Engineering, 2024, 96: 110409. [Google Scholar]
- Permana I, Agharid A P, Wang F. Performance improvement through CFD and field measurement in a unidirectional airflow cleanroom for wafer manufacture[J]. Journal of Building Engineering, 2025, 100: 111715. [Google Scholar]
- Permana I, Agharid A P, Singh N, et al. Full-scale evaluation of FFU configurations in an optical cleanroom injection molding for improving thermal performance and contaminant removal[J]. Case Studies in Thermal Engineering, 2024, 61: 105076. [Google Scholar]
- Wang F, Permana I, Lee K, et al. Improvement of airflow distribution and contamination control for a biotech cleanroom[J]. Atmosphere, 2022, 13(2): 335. [Google Scholar]
- Loomans M G L C, Ludlage T B, van den Oever H, et al. Experimental investigation into cleanroom contamination build-up when applying reduced ventilation and pressure hierarchy conditions as part of demand controlled filtration[J]. Building and Environment, 2020, 176: 106861. [Google Scholar]
- Ma Chengpeng, Zhao Fuyun, Yao Yihe. Study on the Contaminant Removal Performance of a Static Electronic Cleanroom under Different Air Supply Conditions[J]. Journal of Shaoyang University (Natural Science Edition), 2025, 22(01): 88–97.(in Chinese) [Google Scholar]
- Xiao L, Shao K H, Lei F, et al. Experimental study of airborne particle transmission through the doorway of a cleanroom due to the movement of a person[J]. Building and Environment, 2020,183: 107205. [Google Scholar]
- International Organization for Standardization. ISO 14644-4:2001 Clean rooms and associated controlled environments Part 4: Design, construction and startup[S]. Switzerland: ISO Copyright Office, 2001. [Google Scholar]
- IES. RP-CC012.1 Considerations in Cleanroom Design[S]. USA: Institute of Environmental Sciences and Technology, 1995. [Google Scholar]
- Guldana A, Niyetbay S, Zhanguzhinov A, et al. Impact of Airflow Disturbance from Human Motion on Contaminant Control in Cleanroom Environments: A CFD-Based Analysis[J]. Buildings, 2025, 15(13): 2264. [Google Scholar]
- Wissink J. DNS of separating, low Reynolds number flow in a turbine cascade with incoming wakes[J]. International Journal of Heat and Fluid Flow, 2003, 24(4), 626–635. [Google Scholar]
- Benguesmia H, Bakri B, Driss Z, et al. Effect of the turbulence model on the heat ventilation analysis in a box prototype[J]. Diagnostyka, 2020, 21. [Google Scholar]
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.