Calculating the load on the room cooling ceiling panel at convective heat gains
Moscow State University of Civil Engineering, Yaroslavskoye sh., 26, Moscow, 129337, Russia
* Corresponding author: emal@list.ru
A well-known statement of the theory of thermal stability asserts that when a harmonically time-changing convective heat flux enters a room, it can only be assimilated by a radiant cooling system if the assimilating flow exceeds the perturbing convective flow in magnitude. However, in engineering practice, there are no purely radiant systems. Therefore, the article has considered a ceiling cooling panel as a room cooling system, the heat flow from which is of a radiant-convective nature. The convective heat access to the room is constant during the working hours from 9 a.m. to 6 p.m. The task of determining the load on the cooling system has been performed by calculations.. Herewith, the rooms of different internal thermal stability have been considered. According to the calculation results, it has been found that, since the amount of the heat gains remains constant for a long period of time, the process of the room cooling comes almost to a stationary state and does not depend on the room thermal stability with assimilated heat gains, the value of which in different options varied from 100 W to 1000 W. It has been found, that when the temperature difference between the panel surface and the surrounding surfaces increases, the proportion of the convective assimilating flow becomes bigger.
© The Authors, published by EDP Sciences 2020
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.