Development of a statistical model to assess the climate conditions in the ventilation layer of double pitched roofs
Holzforschung Austria (HFA), Division of Building Physics, 1030 Vienna, Austria
* Corresponding author: j.tieben@holzforschung.at
For the proper simulation of hygrothermal processes in roof constructions with ventilation layers the knowledge of climate conditions within the ventilation layer is requisite. In this work a model for the assessment of temperature and air humidity has been developed using multiple regression analysis. Therefore, the climate conditions inside the ventilation layers of differently covered and oriented roofs have been monitored for one year. Relevant outside climate parameters for the calculation of ventilation layer climates have been identified. The comparison between measured and calculated values indicated an adequate accuracy of the developed model with limitations for the use in snow fall periods.
© The Authors, published by EDP Sciences, 2020
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.