Issue |
E3S Web Conf.
Volume 172, 2020
12th Nordic Symposium on Building Physics (NSB 2020)
|
|
---|---|---|
Article Number | 25009 | |
Number of page(s) | 8 | |
Section | Energy performance simulation and assessment | |
DOI | https://doi.org/10.1051/e3sconf/202017225009 | |
Published online | 30 June 2020 |
Modification of building energy simulation tool TRNSYS for modelling nonlinear heat and moisture transfer phenomena by TRNSYS/MATLAB integration
1 Department of Energy and Environmental Engineering, Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, 6-1 Kasuga Koen, Kasuga, Fukuoka 816-8580, Japan
2 School of Mechanical Engineering, Kalinga Institute of Industrial Technology, Bhubaneswar 751024, Odisha, India
* Corresponding author: ajaya.ketana@gmail.com
Software for numerical simulation of various types of energy used in buildings, i.e. building energy simulation (BES), have become an essential tool for recent research pertaining to building physics. TRNSYS is a well-known BES used in both academia and the construction industry for a wide range of simulations, such as the design and performance evaluation of buildings and related facilities for heating, cooling, and ventilation. TRNSYS has a modular structure comprising various components, and each component is interconnected and compiled through a common interface using a FORTRAN compiler. Its modular structure enables interactions with various external numerical simulation tools, such as MATLAB, Python, and ESP-r. For ordinary simulations of building energy load using TRNSYS, the generic module Type 56 is usually recommended, which provides detailed physics modelling of building thermal behaviours based on unsteady energy conservation equations and Fourier’s law for each building material. However, Type 56 explicitly depends on the transfer function method to discretise the original differential equations; therefore, it cannot model nonlinear phenomena, such as latent heat and moisture transfer between a building surface and ambient air. In other words, the current TRNSYS cannot be used to estimate the effectiveness of evaporation during cooling, which is a typical passive design method. Hence, the authors developed a MATLAB/TRNSYS integration scheme, in which TRNSYS was modified to model simultaneous heat and moisture transfer from the wet roof surface of a building. This scheme enabled TRNSYS to calculate the rate of evaporative heat and moisture transfer dynamically from the roof surface, assuming a control volume approximation of the roof surface. Finally, the effect of evaporative cooling on the thermal performance of an Indian building was estimated using the modified model.
© The Authors, published by EDP Sciences, 2020
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.