Issue |
E3S Web Conf.
Volume 252, 2021
2021 International Conference on Power Grid System and Green Energy (PGSGE 2021)
|
|
---|---|---|
Article Number | 02050 | |
Number of page(s) | 4 | |
Section | Research and Development of Electrical Equipment and Energy Nuclear Power Devices | |
DOI | https://doi.org/10.1051/e3sconf/202125202050 | |
Published online | 23 April 2021 |
Numerical simulation on the characteristics of smoke exhaust effect with different sets of smoke vent in deep buried inclined channel fire
1 School of Civil Engineering, Chongqing University, Chongqing, 400045, P.R. China ;
2 Key Laboratory of New Technology for Construction of Cities in Mountain Area of Ministry of Education (Chongqing University), Chongqing, 400045, P.R. China ;
3 Joint International Research Laboratory of Green Buildings & Built Environments, Chongqing, 400045, P.R. China ;
* Corresponding author: Lu Yuhan: Lyhaaan@163.com
Deep buried metro stations require longer and more inclined exit passages to connect with the outside. The fire characteristics of these inclined and narrow passages are significantly different from those of above-ground or shallow buried metro station exit passages, and at the same time fires in those inclined channels have a greater risk. This paper takes a channel of deep buried tunnel station in Chongqing as an example and simplifies the actual passage to establish a 3D model to study the smoke spread characteristics along the passage with different smoke vent characteristics including shape and location by FDS, as well as temperature distribution characteristic under different working conditions. The results show that: after a fire, smoke will spread upwards rapidly under the action of thermal buoyancy, and mechanical smoke exhaust plays a certain role in controlling smoke, which is more obvious at the beginning of the fire; there are differences in the smoke exhaust efficiency of different smoke extraction openings shape, but the differences are small, and square smoke vents have a slightly better effect on smoke control than other shapes of smoke vents; changing the location of smoke outlets has a greater impact on the environment in the tunnel. When the smoke vent is located directly above the fire source, the mechanical smoke control effect is significantly better than other positions, and as the distance between smoke vent and fire source increases, the average temperature along the passage increases. At the same time, because of the pressure difference after the fire, the emergency staircase and the upstream of the fire source are basically unaffected by smoke.
© The Authors, published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.