Issue |
E3S Web Conf.
Volume 366, 2023
The 2021 International Symposium of the Society of Core Analysts (SCA 2021)
|
|
---|---|---|
Article Number | 01009 | |
Number of page(s) | 10 | |
DOI | https://doi.org/10.1051/e3sconf/202336601009 | |
Published online | 27 January 2023 |
Core cleaning and wettability restoration – selecting appropriate method
1.
Lundin-Energy, Norway
2.
PanTerra Geoconsultants, The Netherlands
The core cleaning approaches aim to remove native crude oil, mud filtrates and evaporated salts which leads to strongly water-wet cores. In the standard core cleaning method, the solvent(s) injection continues until no more oil is observed in effluent. This is generally confirmed by visual examination, rather than by analyzing the composition of effluent, simply because it is expensive.
In this work, we selected two preserved rock sections from an oil reservoir in North Sea. 1.5-inch diameter core plugs were cleaned by two different flush cleaning programs (so-called Program-1 and 2). In Program-1, samples were flushed first with 75% toluene + 25% methanol and then followed by alternate of toluene-chloroform-methanol until the samples were deemed cleaned from visual examination. In Program-2, samples were flushed by alternating toluene-tetrahydrofuran-chloroform for 8 cycles. Oil effluents from Program-2 were collected for composition GC analyses.
The efficiencies of two flush cleaning programs were compared by measuring the wettability of the samples by combined Amott-USBM wettability method. The USBM index shows samples after cleaning program-2 are more water wet. Samples were then aged in crude oil at reservoir conditions for 4 weeks. Drainage and imbibition capillary pressure using centrifuge and porous plate and the end-point liquid permeabilities were then measured on restored samples. End-point properties after aging process, showed wettability being restored to intermediate water-wet as is expected from field production history.
This study shows that standard cleaning does not fully clean these samples. Meanwhile, the elaborate Program-2 is often impractical, takes too long, is expensive and limited by laboratory capacity.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.