Issue |
E3S Web of Conf.
Volume 517, 2024
The 10th International Conference on Engineering, Technology, and Industrial Application (ICETIA 2023)
|
|
---|---|---|
Article Number | 13001 | |
Number of page(s) | 4 | |
Section | Mechanics | |
DOI | https://doi.org/10.1051/e3sconf/202451713001 | |
Published online | 15 April 2024 |
Vibration Training System Performance Test – Two Mass Absorber System Experiment
1 Diponegoro University, Mechanical Engineering Departement, Jl. Prof. Sudharto, SH., Tembalang-Semarang 50275.
2 Physics Department, Faculty of Mathematics and Natural Science, Universitas Negeri Semarang, Semarang, Indonesia.
3 Faculty of Mechanical Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100, Durian Tunggal, Melaka, Malaysia.
* Corresponding author: djoeli_satrijo@yahoo.com
Two mass absorber is a vibration control system designed to enhance structural stability by strategically placing additional masses to effectively absorb and dampen vibrations. This technology mitigates resonance and harmful amplitude, reducing the risks of structural failure and operational inefficiencies in diverse engineering applications. Through this innovative approach, structures can withstand dynamic forces and operate efficiently in various fields. The TM 150 unit is used for conducting various experiments related to vibration phenomena. In this paper, experiments are carried out on a flexible beam that is oscillated using an unbalanced mass in the frequency range of 6 Hz to 18 Hz to see at which frequency the flexible beam will resonate. Another variation is to provide two mass absorbers under the flexible beam to see the difference. The experimental resonance graph was produced that was in accordance with the theoretical one, but with different amplitude units due to equipment limitations. The resulting graph shows before the absorber, the flexible beam resonates at its natural frequency. Afterward, small vibrations occur at that point, while resonance shifts. Furthermore, the performance of the vibration test unit is very good in showing the phenomena that occur in accordance with the theory.
© The Authors, published by EDP Sciences, 2024
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.