Impinging jet duct diffuser ventilation effectiveness benchmarking with mixing ventilation in a mock-up classroom
1 Tallinn University of Technology, Estonia
2 Aalto University, Finland
* Corresponding author: This email address is being protected from spambots. You need JavaScript enabled to view it.
Abstract
The benefits of effective classroom ventilation for health and learning outcomes are well known. However, studies continue to report inadequate air quality, insufficient air change rates, and too high air velocities. This study investigated classroom air distribution solutions in the ventilation air distribution laboratory at Tallinn University of Technology. Nozzle diffusers and duct diffusers mounted in the ceiling were compared with two impinging duct diffuser configurations installed on the shorter sides or the single longer wall of the mock-up classroom. Draught risk was assessed using air velocity probes in a mock-up classroom setup with a dedicated room-based air handling unit and thermal dummies simulating student heat loads. Contaminant removal effectiveness was evaluated using the continuous tracer gas injection method with multiple point source locations. Results showed that close to fully mixed ventilation effectiveness was achieved both with ceiling and perimeter impinging ventilation. Measured contaminant removal effectiveness varied across 0.85 to 1.16. The 10° nozzle duct diffuser configuration demonstrated the best performance of impinging ventilation in terms of ventilation effectiveness and draught control. When positioned to the longer side of the room with the extract close to the opposite wall, this configuration further improved overall performance, though it resulted in elevated air velocities at floor level. To avoid draught, the airflow rate needed to be reduced with these perimeter nozzle duct diffusers to 3.3 L/s m2 while the ceiling nozzle and ceiling duct diffusers were capable of 4.5 L/s m2 without draught. The results demonstrate the potential and also a challenge of floor level air velocity of perimeter impinging jet ventilation worth to be further studied for practical applications.
© The Authors, published by EDP Sciences, 2026
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.