Open Access
Issue
E3S Web Conf.
Volume 111, 2019
CLIMA 2019 Congress
Article Number 02018
Number of page(s) 7
Section Indoor Environment Quality and Others
DOI https://doi.org/10.1051/e3sconf/201911102018
Published online 13 August 2019
  1. A. Mecke, I. Lee, J.R. Baker jr., M. M. Banaszak Holl, B.G. Orr, Eur. Phys. J .E 14, 7 (2004) [CrossRef] [PubMed] [Google Scholar]
  2. Abadie, M., Contribution à l’étude de la pollution particulaire : rôle des parois, rôle de la ventilation, in LEPTAB. 2000, Université de La Rochelle. [Google Scholar]
  3. Fanger, P.O., ed. Thermal Comfort-Analysis and Applications in Environmental Engineering. ed. C.D.T. Press. 1970. [Google Scholar]
  4. Meslem, A., Contribution à l’étude du couplage thermique entre un jet et un local climatisé. 1997, INSA Lyon. [Google Scholar]
  5. Kosonen, R., et al., Impact of heat load location and strength on air flow pattern with a passive chilled beam system Energy and Buildings, 2010. 42 (1): p. 34-42. [Google Scholar]
  6. Einberg, G., et al., CFD modeling of an industrial air diffuser-predicting velocity and temperature in the near zone. Building and Environment 2005. 40: p. 601-615. [Google Scholar]
  7. Meslem, A., et al., A comparison of three turbulence models for the prediction of parallel lobed jets in perforated panel optimization. Building and Environment, 2011. 46 (11): p. 2203-2219. [Google Scholar]
  8. Inard, C., H. Bouia, and P. Dalicieux, Prediction of air temperature distribution in buildings with a zonal model. Energy and Buildings, 1996. 24 (2): p. 125-132. [Google Scholar]
  9. Inard, C., P. Depecker, and J.-J. Roux, Un modèle simplifié pour la prédiction du champ de température dans les bâtimentsA simplified model for the prediction of air temperature distribution in buildings. Révue Générale de Thermique, 1997. 36 (2): p. 113-123. [CrossRef] [Google Scholar]
  10. Inard, C., et al., Structure moyenne et anlyse intégrale du panache thermique des convecteurs électriques. Révue Générale de Thermique, 1997. 36: p. 495-509. [CrossRef] [Google Scholar]
  11. Awbi, H.B., Ventilation of Buildings. 2003, London, U.K.: E&FN SPON. 313. [Google Scholar]
  12. Fanger, P.O., et al., Air turbulence and sensation of draught. Energy and Buildings, 1988. 12 (1): p. 21-39. [Google Scholar]
  13. Fanger, P.O., The new comfort equation for indoor air quality. Ashrae Journal, 1989. 31 (10): p. 33-38. [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.