Open Access
Issue
E3S Web Conf.
Volume 328, 2021
International Conference on Science and Technology (ICST 2021)
Article Number 02006
Number of page(s) 4
Section Electrical, Intrumentation and control, Dynamic Electricity
DOI https://doi.org/10.1051/e3sconf/202132802006
Published online 06 December 2021
  1. B. Bridger, “Metal-Clad Switchgear or Metal-Enclosed Switchgear : Which is it ? Metal-Clad Switchgear or Metal-Enclosed Switchgear : Which is it?”. Powell Industries, Inc, (1996). [Google Scholar]
  2. Suwarno, “Diagnosis of High Voltage Equipments”, Penerbit ITB, Bandung, (2010). [Google Scholar]
  3. A. Balanis, “Antenna Theory Analysis and Design, Third Edition”, Canada: A Jonh Wiley & Sons, INC, (2005). [Google Scholar]
  4. D. T. Laksono and U. Khayam, “Comparison of peak to peak voltage and number of partial discharge detected by HFCT and loop antenna in metal enclosed high voltage equipment,” 2017 International Conference on High Voltage Engineering and Power Systems (ICHVEPS), pp. 466-471,(2017). doi: 10.1109/ICHVEPS.2017.8225891 [CrossRef] [Google Scholar]
  5. Deni Tri Laksono et al, “10 Segment Spiral Antenna to Measure Partial Discharge on High Voltage Equipment“ IOP Conf. Ser.: Mater. Sci. Eng. 1125 012071, (2021). [CrossRef] [Google Scholar]
  6. Deni Tri Laksono et al, ”Comparison of Partial Discharge Characteristics Detected by RC Detector and Rectangular Antenna”. J. Phys.: Conf. Ser. 1569 032086, (2020). [CrossRef] [Google Scholar]
  7. Dedi Tri Laksono et al, “Comparative Measurement of Partial Discharge Using Spiral Antenna with RC Detector on High Voltage Equipment“ (2020) J. Phys.: Conf. Ser. 1569 032089 [CrossRef] [Google Scholar]
  8. D. T. Laksono and U. Khayam, “Effect of the presence of metal box on partial discharge waveform and pattern detected by high frequency current transformer,” 2017 International Conference on High Voltage Engineering and Power Systems (ICHVEPS), (2017), pp. 331-334, doi: 10.1109/ICHVEPS.2017.8225967. [Google Scholar]
  9. F. Álvarez, F. Garnacho, A. Khamlichi and J. Ortego, “Classification of partial discharge sources by the characterization of the pulses waveform,” 2016 IEEE International Conference on Dielectrics (ICD), (2016), pp. 514-519, doi: 10.1109/ICD.2016.7547655. [CrossRef] [Google Scholar]
  10. Suwarno, “Partial discharges in high voltage insulations: Mechanism, patterns and diagnosis,” 2014 International Conference on Electrical Engineering and Computer Science (ICEECS), (2014), pp. 369-375, doi: 10.1109/ICEECS.2014.7045280. [Google Scholar]
  11. Y. M. Hamdani and U. Khayam, “Application of Circular Patch Microstrip Antenna (CPMA) for Partial Discharge Detector in oil insulation,” 2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS), (2019), pp. 1-6, doi: 10.1109/ICHVEPS47643.2019.9011052. [Google Scholar]
  12. Z. Zeng, Y. Hu and W. Zhang, “An External UHF Miniaturized Compound Spiral Slot Antenna for Partial Discharge Detection in GIS,” 2020 8th International Conference on Condition Monitoring and Diagnosis (CMD), (2020), pp. 198-201, doi: 10.1109/CMD48350.2020.9287177. [Google Scholar]
  13. J. P. Uwiringiyimana and U. Khayam, “Measurement of Partial Discharge in Air Insulation by using UHF Double Layer Bowtie Antenna with Modified Wings Edges,” 2019 International Conference on Electrical Engineering and Informatics (ICEEI), (2019), pp. 228-233, doi: 10.1109/ICEEI47359.2019.8988866. [Google Scholar]
  14. G. Robles et al., “On the use of Vivaldi antennas in the detection of partial discharges,” 2013 IEEE International Conference on Solid Dielectrics (ICSD), (2013), pp. 302-305, doi: 10.1109/ICSD.2013.6619887. [Google Scholar]
  15. “IEEE Recommended Practice for Partial Discharge Measurements under AC Voltage with VHF/UHF Sensors during Routine Tests on Factory and Pre-Molded Joints of HVDC Extruded Cable Systems up to 800 kV,” in IEEE Std 2862-2020, vol., no., pp.1-31, 8 March (2021), doi: 10.1109/IEEESTD.2021.9374151. [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.